Minifog ProCon XP

High pressure water mist systems

    Mini­fog Pro­Con XP High Pres­sure Water Mist Sys­tem

    Mini­fog Pro­Con XP high pres­sure water mist sys­tems offer ex­cel­lent fire pro­tec­tion along with a min­imum con­sump­tion of ex­tin­guish­ing water, e.g. for sys­tems in con­fined spaces. Mini­fog Pro­Con XP uses ap­prox. 95 per­cent less ex­tin­guish­ing water com­pared to con­ven­tional spray water ex­tin­guish­ing sys­tems. This ex­tremely low con­sump­tion of ex­tin­guish­ing water re­duces the risk of water dam­age and thermal dis­tor­tion of hot ma­chine parts to a min­imum. The water sup­ply unit can be de­signed in a more com­pact format. This saves space, on-site costs and makes ret­ro­fit­ting easier.

    • Mini­fog Pro­Con XP pro­tects en­gines, tur­bines and other equip­ment
    • Sub­stan­tial in­vest­ments are pro­tec­ted and long and costly down­times can be pre­ven­ted
    • The use of water means that no spe­cific health and safety meas­ures are re­quired to pro­tect people against the ex­tin­guishant
    • Com­pared to clas­sic water spray sys­tems, Mini­fog Pro­Con XP re­duces water con­sump­tion by up to 95%
    • Mini­fog Pro­Con XP of­fers pro­tec­tion of large spaces with a di­men­sion of up to 2,430m³ and a height of up to 13.5m
    • The Mini­fog Pro­Con XP sys­tem can be de­signed as a multi-zone sys­tem even when the water is sup­plied via cyl­in­der bat­tery
    • En­hanced pro­tec­tion against re­igni­tion: The Con­stant­Flow tech­no­logy keeps the sys­tem pres­sure con­stant throughout the en­tire op­er­at­ing time even if the water is sup­plied via cyl­in­der bat­tery
    • The use of the well-proven Minimax fire de­tec­tion and con­trol tech­no­logy en­sures op­timum com­pat­ib­il­ity of elec­trical and mech­an­ical sys­tem com­pon­ents

      Protected Area

      1

      Op­tical alarm

      2

      Manual call point

      3

      Fire de­tec­tion and ex­tin­guish­ing con­trol panel

      4

      Pro­Con XP nozzle

      5

      Fire de­tector

      6

      Water sup­ply unit

      7

      Acous­tic alarm

      8

      En­gine test bed

      9

      Se­lector valves
      1. 1Op­tical alarm
      2. 2Manual call point
      3. 3Fire de­tec­tion and ex­tin­guish­ing con­trol panel
      4. 4Pro­Con XP nozzle
      5. 5Fire de­tector
      6. 6Water sup­ply unit
      7. 7Acous­tic alarm
      8. 8En­gine test bed
      9. 9Se­lector valves
      Fire de­tec­tion and ex­tin­guish­ing con­trol tech­no­logy
      • Ideally, the ex­tin­guish­ing zones are mon­itored by fast and re­li­able Uni­Vario flame de­tect­ors, which trans­mit a sig­nal to the FMZ6000 fire de­tec­tion and ex­tin­guish­ing con­trol panel in the event of fire. Ad­di­tion­ally, the ex­tin­guish­ing zones are equipped with elec­trical push-but­ton de­tect­ors for manual ac­tiv­a­tion of the Mini­fog Pro­Con XP sys­tem. In the event of fire, the fire de­tec­tion and ex­tin­guish­ing con­trol panel ac­tiv­ates the water sup­ply unit and, in multi-zone sys­tems, the cor­res­pond­ing se­lector valve. At the same time, it trig­gers an acous­tic and op­tical alarm and trans­mits a sig­nal to a per­man­ently manned post.

      Applications

      No description available

      https://res.cloudinary.com/djhqy6mok/image/upload/v1725431396/emergency_wj1boi.jpg

      Emer­gency power gen­er­at­ors

      https://res.cloudinary.com/djhqy6mok/image/upload/v1725431398/turbines_piv1ze.jpg

      Gas turbines

      https://res.cloudinary.com/djhqy6mok/image/upload/v1725431395/hydricially_a9rvlq.jpg

      Hy­draul­ics rooms

      https://res.cloudinary.com/djhqy6mok/image/upload/v1725431396/machine_evfvca.jpg

      Ma­chine tool

      https://res.cloudinary.com/djhqy6mok/image/upload/v1725431397/transforms_wytj5f.jpg

      Trans­formers

      Bizi izləyin