Clunid FMZ6000

Innovative low-pressure technology for effective building protection.

Fight­ing fire ef­fi­ciently with water mist

The Mini­fog Eco­n­Aqua water mist ex­tin­guish­ing sys­tem of­fers par­tic­u­larly ef­fi­cient build­ing pro­tec­tion through the use of in­nov­at­ive low-pres­sure water mist tech­no­logy. Com­pared to con­ven­tional sprink­ler sys­tems, the Eco­n­Aqua sys­tem uses up to 85 per­cent less ex­tin­guish­ing water, re­du­cing po­ten­tial water dam­age to a min­imum. The Eco­n­Aqua con­trol panel can also be de­signed much more com­pactly than a clas­sic sprink­ler sys­tem. This saves space and on-site costs and makes the Mini­fog Eco­n­Aqua water mist ex­tin­guish­ing sys­tem ideal for ret­ro­fit­ting in ex­ist­ing build­ings.

Newly de­veloped - Eco­n­Aqua Car Park

Thanks to the de­vel­op­ment of the Eco­n­Aqua Water Mist Sprink­ler U16, Eco­n­Aqua is now the low-pres­sure water mist sys­tem with the widest range of ap­plic­a­tions on the mar­ket. Fur­ther­more, it is the only sys­tem ap­proved by the VdS for use in multi-storey and un­der­ground park­ing lots with a ceil­ing height of up to 3.6 meters.

Ef­fic­acy con­firmed - VdS ap­proval re­ceived

The ef­fect­ive­ness of the new Eco­n­Aqua U16 sprink­ler has been veri­fied with a range of ex­tens­ive fire tests under the su­per­vi­sion of VdS Schaden­verhütung. They were car­ried out at the Minimax Fire Re­search Cen­ter based on cur­rent VdS and EN re­quire­ments. In the test setup for a typ­ical park­ing gar­age situ­ation, the ef­fect­ive­ness of Eco­n­Aqua was com­pared to a con­ven­tional dry sprink­ler sys­tem as per VdS CEA 4001 (in­clud­ing a safety mar­gin)The Eco­n­Aqua sys­tem suc­cess­fully passed the fire tests. Fur­ther­more, it was veri­fied that the Eco­n­Aqua low-pres­sure water mist sys­tem provides the same fire pro­tec­tion as con­ven­tional sprink­ler sys­tems but at a lower water con­sump­tion, thus of­fer­ing a higher ef­fi­ciency.

Ad­vant­ages at a glance

  • VdS-ap­proved low-pres­sure water mist sys­tem with the widest ap­plic­a­tion area on the mar­ket
  • Ef­fi­cient use of ex­tin­guish­ing water helps to re­duce the amount of water dam­age
  • Eco­n­Aqua sprink­lers cover lar­ger pro­tec­ted areas than con­ven­tional sprink­lers
  • Can also be used as a dry sys­tem without pipe trace heat­ing or an­ti­freeze in frost-prone areas
  • Re­quires less in­stall­a­tion space thanks to smal­ler nom­inal pipe widths due to lower ex­tin­guish­ing water re­quire­ment

        Protected Area

        1

        Eco­n­Aqua sec­tion valve set wet

        2

        Fire de­tec­tion and con­trol panel

        3

        Eco­n­Aqua sec­tion valve set dry

        4

        Com­pressor unit

        5

        Dry pipe sys­tem for rooms sub­ject to frost haz­ard

        6

        Stor­age tank

        7

        Pump con­trol cab­inet

        8

        Wet pipe sys­tem for frost-pro­tec­ted rooms

        9

        Eco­n­Aqua mas­ter pump

        10

        Alarm sta­tion Eco­n­Aqua
        1. 1Eco­n­Aqua sec­tion valve set wet
        2. 2 Fire de­tec­tion and con­trol panel
        3. 3Eco­n­Aqua sec­tion valve set dry
        4. 4Com­pressor unit
        5. 5Dry pipe sys­tem for rooms sub­ject to frost haz­ard
        6. 6Stor­age tank
        7. 7Pump con­trol cab­inet
        8. 8Wet pipe sys­tem for frost-pro­tec­ted rooms
        9. 9Eco­n­Aqua mas­ter pump
        10. 10Alarm sta­tion Eco­n­Aqua
        • The nom­inal pipe dia­met­ers used in these areas mainly lie between DN20 and DN40 and are much smal­ler than those used in clas­sic sprink­ler pipe­work. In standby con­di­tions the pipe­work in the sec­tions is filled with pres­sur­ized water (wet sys­tem for frost-proof rooms) or with com­pressed air or ni­tro­gen (dry sys­tem for rooms sub­ject to frost haz­ard). In the event of a fire, the water mist sprink­lers loc­ated in the im­me­di­ate vi­cin­ity of the fire ac­tiv­ate.

        Applications

        The Mini­fog Eco­n­Aqua water mist sprink­ler sys­tems can be used for a num­ber of ap­plic­a­tions, cov­er­ing sev­eral fire haz­ard classes. Classes which are defined in the VdS guidelines for sprink­ler sys­tems (VdS CEA 4001).

        https://res.cloudinary.com/djhqy6mok/image/upload/v1725430673/hotel_ylf6iy.jpg

        Hotel rooms

        https://res.cloudinary.com/djhqy6mok/image/upload/v1725430782/offices_gxeuju.jpg

        Of­fices

        https://res.cloudinary.com/djhqy6mok/image/upload/v1725430782/parking_yb8xzd.jpg

        Park­ing areas

        Bizi izləyin