HELIOS Aspirating smoke detectors

Large-scale dampening.

Ad­vant­ages of the HE­LIOS as­pir­at­ing smoke de­tect­ors

HE­LIOS AMX5000 as­pir­at­ing smoke de­tect­ors de­tect even minute smol­der­ing fires and can be used al­most any­where. They act­ively draw air samples from the pro­tec­tion zone and ana­lyze them in a meas­ur­ing cham­ber. In ad­di­tion to a pre-sig­nal and con­tam­in­a­tion as­sess­ment, the de­tector also of­fers the pos­sib­il­ity of ad­just­ing the sens­it­iv­ity in ac­cord­ance with the unit's gen­eral use. Minimax as­pir­at­ing smoke de­tect­ors are mul­ti­func­tional de­tect­ors that re­spond to vari­ous fire char­ac­ter­ist­ics through com­bined meas­ur­ing cham­ber sys­tems. Thus, fires are already de­tec­ted at an early stage.

    HE­LIOS AMX5000 as­pir­at­ing smoke de­tector series:

    • Auto-learn­ing func­tion.
    • Sep­ar­ate air stream mon­it­or­ing with one or two suc­tion lines.
    • Ad­justable sens­it­iv­ity from 0.002–10%/m.
    • Ex­cel­lent suc­tion power (more than 400 Pa neg­at­ive pres­sure).
    • Highly sens­it­ive smoke de­tect­ors with con­tam­in­a­tion bal­ance for use in crit­ical areas.
    • The VdS-tested HE­LIOS Pipe­Calc cal­cu­la­tion soft­ware en­sures ef­fi­cient, asym­met­rical pipe in­stall­a­tion.
    • Can be com­pletely in­teg­rated with the Minimax FMZ 5000 fire alarm sys­tem.
    • Simple con­fig­ur­a­tion and start-up of stand­ard devices using HE­LIOS Easy­Con­fig.

      Design and func­tion

      The HE­LIOS AMX5000 as­pir­at­ing smoke de­tector con­sists of one or two in­de­pend­ent suc­tion lines with suc­tion open­ing and one highly sens­it­ive smoke sensor. Each suc­tion line is con­stantly mon­itored via an air stream mon­it­or­ing sys­tem in order to identify pipe breaks and dirt at the suc­tion open­ing. A high-power fan sucks air from the area or device to be mon­itored through the suc­tion line to an eval­u­ation unit. Here, the air is con­stantly eval­u­ated by the smoke sensors. The dis­play and op­er­at­ing fields of the eval­u­ation unit show the smoke con­cen­tra­tion in the as­pir­ated air, in ad­di­tion to other alarm, fault and status no­ti­fic­a­tions. Any in­crease in the smoke con­cen­tra­tion is iden­ti­fied ex­tremely quickly. Three pre-sig­nals and one main alarm can be pro­grammed, which can be trans­ferred to the Loop AP via a po­ten­tial-free relay or mod­ule.

        Protected Area

        1

        Alarm threshold HE­LIOS AMX5000

        2

        Alarm threshold of con­ven­tional smoke de­tect­ors
        1. 1Alarm threshold HE­LIOS AMX5000
        2. 2Alarm threshold of con­ven­tional smoke de­tect­ors

          Applications

          The HE­LIOS AMX5000 is also suit­able for room and ob­ject ob­ser­va­tion thanks to its ex­cel­lent re­sponse char­ac­ter­ist­ics. After in­stall­a­tion, the pipe sys­tem is largely in­vis­ible, thus en­sur­ing pro­tec­tion for cul­tural pos­ses­sions and op­timum suit­ab­il­ity for prison cells and aes­thet­ic­ally de­mand­ing ar­chi­tec­ture.

          https://res.cloudinary.com/djhqy6mok/image/upload/v1725390467/high_hptdzf.jpg

          High rack stor­age

          https://res.cloudinary.com/djhqy6mok/image/upload/v1725390464/refApp_jviusk.jpg

          Re­fri­ger­ated stor­age

          https://res.cloudinary.com/djhqy6mok/image/upload/v1725390465/serverApp_fgoguh.jpg

          Server rooms

          Bizi izləyin