CPS 1230 Cab­inet pro­tec­tion sys­tems

Complete and compact

Cab­inet Pro­tec­tion - com­plete and com­pact

Switch and con­trol cab­in­ets, along with vend­ing ma­chines, con­tain elec­tronic and elec­tric com­pon­ents in very con­fined spaces. CPS 1230 ex­tin­guish­ing sys­tems pro­tect this type of cab­inet in case a fire oc­curs in­side them as a res­ult of a short cir­cuit, over­load, over­heat­ing or a com­pon­ent error.

    Ad­vant­ages at a glance

    The CPS 1230 cab­inet pro­tec­tion sys­tem (CPS) is a stand­ard­ized com­pre­hens­ive set with all ne­ces­sary com­pon­ents in one pack­age. The sys­tem is spe­cially de­signed for fire pro­tec­tion of the sens­it­ive and high-qual­ity elec­tron­ics in con­trol cab­in­ets and of­fers re­li­able and residue-free ex­tin­guish­ing through the use of the non-con­duct­ive FK 5-1-12. The com­pre­hens­ive set can be eas­ily in­stalled on site, both in the case of new in­stall­a­tions and ret­ro­fits.

    • CPS 1230 ex­tin­guish­ing sys­tems pro­tect cab­in­ets with elec­tronic and elec­tric com­pon­ents
    • The sys­tem pre­vents the fire from spread­ing to other fa­cil­it­ies in the vi­cin­ity of the pro­tec­ted cab­in­ets
    • No ex­ten­ded down­times in en­ergy sup­ply and pro­duc­tion fa­cil­it­ies
    • One sys­tem can pro­tect up to two cab­in­ets
    • The Novec 1230 ex­tin­guish­ing agent is neither cor­ros­ive nor elec­tric­ally con­duct­ive and does not leave any residues
    • New sys­tems can be eas­ily and quickly in­stalled or ret­ro­fit­ted

      Design

      The CPS 1230 ex­tin­guish­ing sys­tem con­sists of the ex­tin­guish­ing nozzles with the as­so­ci­ated sup­ply lines, the ex­tin­guish­ing tank as well as the fire de­tec­tion and ex­tin­guish­ing con­trol sys­tem. One sys­tem pro­tects up to two cab­in­ets with elec­tronic and elec­tric com­pon­ents.

      CPS 1230 ex­tin­guish­ing sys­tems fight fires in the cab­in­ets that are to be pro­tec­ted, using the FK 5-1-12 ex­tin­guish­ing agent by 3MTM. The ex­tin­guish­ing agent ex­tracts heat from the fire and thus stops the com­bus­tion re­ac­tion. The Novec 1230 ex­tin­guish­ing agent is stored in a li­quid state in an ex­tin­guish­ing agent tank. The ex­tin­guish­ing agent is trans­formed into a gaseous state only when it is re­leased from the ex­tin­guish­ing nozzles into the cab­in­ets that are to be pro­tec­ted. FK 5-1-12 is neither cor­ros­ive nor elec­tric­ally con­duct­ive, leaves no residues and is highly en­vir­on­ment­ally friendly.

        Protected Area

        1

        Smoke de­tector

        2

        Fire de­tec­tion and ex­tin­guish­ing con­trol panel

        3

        Ex­tin­guish­ing agent sup­ply

        4

        Elec­tric horn

        5

        Ex­tin­guish­ing agent line

        6

        Ex­tin­guish­ing agent nozzle
        1. 1Smoke de­tector
        2. 2 Fire de­tec­tion and ex­tin­guish­ing con­trol panel
        3. 3Ex­tin­guish­ing agent sup­ply
        4. 4Elec­tric horn
        5. 5 Ex­tin­guish­ing agent line
        6. 6 Ex­tin­guish­ing agent nozzle

        How does a switch cab­inet ex­tin­guish­ing sys­tem work?

        CPS 1230 ex­tin­guish­ing sys­tems fight fires in the cab­in­ets that are to be pro­tec­ted, using the FK 5-1-12 ex­tin­guish­ing agent by 3MTM. The ex­tin­guish­ing agent ex­tracts heat from the fire and thus stops the com­bus­tion re­ac­tion. The Novec 1230 ex­tin­guish­ing agent is stored in a li­quid state in an ex­tin­guish­ing agent tank. The ex­tin­guish­ing agent is trans­formed into a gaseous state only when it is re­leased from the ex­tin­guish­ing nozzles into the cab­in­ets that are to be pro­tec­ted. FK 5-1-12 is neither cor­ros­ive nor elec­tric­ally con­duct­ive, leaves no residues and is highly en­vir­on­ment­ally friendly.

        A CPS 1230 ex­tin­guish­ing sys­tem can pro­tect up to two cab­in­ets with elec­tronic and elec­tric com­pon­ents. Thanks to pre­fab­ric­ated com­pon­ent sets, it is easy and quick to in­stall new sys­tems or to ret­ro­fit ex­ist­ing ones. CPS 1230 ex­tin­guish­ing sys­tems pro­tect in the case of fire not only the ac­tual cab­in­ets, but also pre­vent the fire spread­ing to other devices in their vi­cin­ity.

        A CPS 1230 ex­tin­guish­ing sys­tem can pro­tect up to two cab­in­ets with elec­tronic and elec­tric com­pon­ents. Thanks to pre­fab­ric­ated com­pon­ent sets, it is easy and quick to in­stall new sys­tems or to ret­ro­fit ex­ist­ing ones. CPS 1230 ex­tin­guish­ing sys­tems pro­tect in the case of fire not only the ac­tual cab­in­ets, but also pre­vent the fire spread­ing to other devices in their vi­cin­ity.

        Fire de­tec­tion and con­trol tech­no­logy
        • Tried and tested Minimax fire de­tec­tion and ex­tin­guish­ing con­trol tech­no­logy en­sures re­li­able fire de­tec­tion as well as con­trol and func­tion mon­it­or­ing of the sys­tem. Each pro­tec­ted cab­inet is mon­itored by smoke de­tect­ors. Un­like heat de­tect­ors, these already trans­mit a sig­nal to the fire de­tec­tion and ex­tin­guish­ing con­trol panel in the ini­tial stages of a fire.
        • The con­trol panel then ini­ti­ates the shut­down of the en­ergy sup­ply of the cab­inet and con­trols the elec­tric trig­ger­ing device of the ex­tin­guish­ing agent tank to en­sure that the ex­tin­guish­ing agent can flow into the cab­inet. At the same time, it trig­gers an alarm and op­tion­ally trans­mits a sig­nal to a per­man­ently manned post.

        Applications

        CPS 1230 Cab­inet pro­tec­tion sys­tems are an ideal fire pro­tec­tion solu­tion in many cases, e.g. for Switch cab­in­ets in low-voltage switch sys­tems, Con­trol cab­in­ets for pro­duc­tion sys­tems or Vend­ing ma­chines for goods and ser­vices in con­nec­tion with com­muter trans­port­a­tion sys­tems. CPS 1230 ex­tin­guish­ing sys­tems for cab­inet pro­tec­tion not only pro­tect prop­erty, but also pre­vent en­ergy sup­ply and pro­duc­tion fa­cil­it­ies from longer down­times.